Technics KN7000 · Memories and savingStore your set-up in a panel memory
Panel memories
A panel memory stores the panel’s current settings: the sounds on each part, the style, the tempo, the effects and the volumes. Pressing its number button recalls them. Source: Manual, pp. 22, 65
The KN7000 has 13 banks of 8 panel memories: banks A, B and C, then banks 1 to 10. That’s 104 memories. Source: Manual, pp. 22, 207
The panel is the area above the keys with the buttons, sliders, dial and display. The PANEL MEMORY buttons are on the right of the panel, near the bottom. Source: Tested on a KN7000
Storing
- Set the sounds, style, tempo, effects and volumes.
- Press BANK VIEW to turn it on. The screen shows BANK SELECT.
- Holding any PANEL MEMORY number button for a few seconds also opens this screen.
- Choose a bank with the BANK ∧ and BANK ∨ buttons by the screen.
- The banks are on two pages. The PAGE buttons switch between them.
- Hold SET and press a PANEL MEMORY number button, 1 to 8.
- The number buttons are the ring round SET, with 1 at the left. Source: Tested on a KN7000
The settings are now stored in that bank and number. Source: Manual, p. 65
Storing replaces what the memory held before. Source: Inferred
Without the bank screen: press NEXT BANK until the screen shows the bank, then hold SET and press a number button. Source: Manual, p. 22
Recalling
- Press BANK VIEW and choose the bank, or press NEXT BANK until it shows.
- Press the number button, 1 to 8. The panel changes to the stored settings.
The top line of the screen shows the bank, the memory number and the memory’s name. Changes made after recalling don’t alter the memory until it’s stored again. Source: Manual, p. 66
Options
- A panel memory normally recalls the style and tempo too. To recall memories without them, hold SET for a few seconds and choose NORMAL on the PANEL MEMORY MODE screen. Source: Manual, p. 22
- To name a bank or a memory, go to page 3 of the bank screen with PAGE, then press BANK NAMING or MEMORY NAMING. Source: Manual, p. 66
- A foot switch (sold separately) or the pads’ Control Preset bank can also change panel memories. Source: Manual, p. 66
Power, saving and loading
- With the power off, panel memories are kept for about a week. The backup only works once the keyboard has been on for about 10 minutes. Source: Manual, p. 198
- To keep them longer, save them to an SD card or floppy. Source: Manual, p. 198 Panel memories saved to an SD card load back correctly. Source: Tested on a KN7000
- Loading a save that contains panel memories replaces the ones in the keyboard. To keep the current ones, set P.MEM to NO on LOAD OPTION, page 2 of the SD card’s load screen. Source: Manual, pp. 140, 141
Manual pages
KN7000 owner's manual, pp. 22, 65–66.
Corrections: hello@knarrangers.com
Guide M1 · last checked 13 Nov 2026